OKM and OKM-1 fire protection roof mastics.
printable versionDesign for making fire protection belts on the roof of various buildings and constructions.
TU 5775-002-47935838-99 with change 1
Fire Safety Certificate SSPB.RU
Sanitary Expertise
Application Manual
Quality Certificate
Parameter | Standard | |
OKM | OKM-1 | |
Appearance | Gray paste | |
Cover appearance | Uniform, without flaws or scaling | |
Volume mass, g/cm³ | 1.1 - 1.9 | 1.1 - 1.9 |
Fire protection properties: - combustion group GOST30244-94 - flame spreading group GOST R51032-97 - inflammation group GOST 30402-96 |
NG - - |
G1 RP1 V2 |
Adhesion, points (grating cut method) | 1 | 1 |
Bending strength, mm | 1 | 1 |
APPLICATION METHOD
Before applying the mastics clean the roof surface from dirt, loose particles, etc. There must be no visible condensate or water on the surface. Mastics are supplied ready to use. Before application mix carefully. Apply the mastic with a mechanical device or by hand.
The necessary amount without loss is 5.6 kg/m² with the dry layer thickness of 3 mm. If the cover is damaged it can be restored by applying the mastic to the damage place.
The first layer drying time is not more than 24 hours is favorable drying conditions - air temperature 20º±5ºC, relative air humidity not more than 85%. The time interval between the two layers can be more than 24 hours. Apply the next layer after the previous one has dried.
TRANSPORTATION AND STORAGE REQUIREMENTS
OKM and OKM-1 mastics are not hazardous and can be transported by any kind of covered vehicle according to the rules for the particular vehicle.
Keep the mastics in hermetically closed metal containers at temperatures not less than +5ºC with relative humidity up to 80%.
WARRANTED PERIOD
Storage period for OKM and OKM-1 ready to use fire protection roof covers according to TU 5775-002-47935838-99 with change 1 in tightly closed containers is 4 month.